Alesis QS7.1 Instruction Manual Page 147

  • Download
  • Add to my manuals
  • Print
  • Page
    / 188
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 146
Editing Programs: Part 8
QS7.1/QS8.1 Reference Manual
Delay (00 to 99) Page 5
This is the amount of time that the envelope will wait before doing anything; very
useful if you want to affect one element of a sound sometime after the sound starts.
When the Delay is set to 0, the envelope begins its attack segment right away,
without any delay. Play some notes while turning up the delay and see that the time
between playing the note and hearing the effect of the Filter Envelope gets
progressively longer as the Delay control is turned up.
If the Delay is set above 99, the display will read “Hold”. This indicates that the
Delay stage of the envelope will wait indefinitely until the key is released before
continuing on to the remaining envelope stages (Attack, Decay, etc.). With a value of
“Hold”, the Pitch Envelope’s Trigger parameter is automatically set to “Freerun” in
the software (see below). However, the displayed value of that parameter is not
changed; only its behavior is.
Sustain Decay (00 to 99) Page 6
This is the amount of time that the envelope will take during the sustain stage to
bring the level down to 0. If this is set to 99, the envelope will remain at the Sustain
level until the note is released. This is the normal setting for organ-type sounds.
When set to 0, the envelope’s level will immediately jump down to 0 upon reaching
the sustain stage.
Trigger (Normal, Freerun, Reset, Reset-Freerun) Page 7
The Trigger mode determines how the envelope will function. You may select either
Freerun or Reset, or both (Reset-Freerun) or neither (Normal). When set to Normal,
the envelope will always start at its current level (i.e., if another note had been played
which triggered the envelope’s cycle, playing another note in the middle would not
interrupt the cycle). Also in Normal mode, the envelope will immediately advance to
its release stage upon releasing the note. When set to Freerun, the envelope will
complete its entire cycle, even if the note is released in the middle. When set to Reset,
the envelope starts at the beginning whenever a new note is played. When set to
Reset-Freerun, the envelope will start at the beginning whenever a new note is
played
and
will complete its entire cycle, even if the note is released in the middle.
If a Sound layer’s Keyboard Mode parameter (found in the Pitch Function, Page 10)
is set to “Mono”, the Filter Envelope will only retrigger when playing legato if the
Trigger Mode is set to either “Reset” or “Reset-Freerun”.
To get the most natural-sounding Sustain Pedal reaction, the best setting for the Filter
Envelope Trigger Mode is usually either the FREERUN or the RESET-FREERUN
mode. This allows the Filter to keep following its envelope shape even after the keys
are lifted up.
TIP:
Page view 146
1 2 ... 142 143 144 145 146 147 148 149 150 151 152 ... 187 188

Comments to this Manuals

No comments